Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr
58 98-1671 Rev AA User Guide
For example, if the user wants testing to confirm that the module firmware version is 07.06, this
parameter can be specified in the Module Firmware field of the Edit Multiple Meter Mode Test
Configuration dialog. When the test is run, ETM will read the module firmware version from the
meter and compare it with the user-specified value. If these values do not match, an error will
display.
Clicking File | Multiple Meter Mode | Run Test will open the Multiple Device Test Results
screen. Meters to be tested are entered using the Add button at the lower left of that screen.
Figure 3 - 27. Multiple Device Test Results Screen
When the Multiple Device Test screen opens, ETM waits for a device ID to be entered so that it can
begin testing. Testing can be halted by clicking the Stop button. After a Module ID is added, testing
begins on the first device in the list, continuing through the entire list.
Devices that pass testing will populate the columns with data selected on the Edit Multiple Meter
Test Configuration dialog. Modules that fail testing will display Fail in a red-highlighted cell in the
Test Status column. If the user hovers their cursor over the Fail indication, the reason for the failure
will appear.
The user can Retry testing on the selected module by clicking that button. Pressing the Ctrl+A keys
selects all modules in the list.
When testing is not active, the user can use the buttons at lower right to Clear WAN Nodes in the
test, and Close the Multiple Device Test screen.
After testing concludes, a log file is created and placed under the Multiple Meter Testing folder in
the ETM installation directory.
Firmware Download Tab
The Firmware Download tab allows you to view the current firmware on the module and download
a new firmware.
For Modular Focus AX meters running 5.13 module firmware and above, ETM now supports
metrology firmware download over the air. This action functions in a manner similar to Module/
HAN firmware download.
For Integrated Focus AX meters, only the Module Firmware option appears. The metrology
firmware upgrade occurs automatically within the build.