Landis+Gyr Chapter 3 - Using Endpoint Testing Manager (ETM)
User Guide 98-1671 Rev AA 53
Scan Meter ID Scan or manually enter the meter ID of the meter to be tested.
“Find device” <>
Opens the Find device dialog for entering the Network Address and used to
locate a device that is a neighbor of the head-end. This function looks at the
neighboring devices of the head-end radio to see if there is one device that
has the same WAN address. If found, the function pulls the module ID of
that device and displays it in the Scan Module ID box.
Start Test <button> Click this button to begin a meter test.
Reset Test <button> Clicking this button resets the input fields.
Module Test Results (these fields will only be populated after the tested endpoint has passed the test and
communicated parameters to ETM)
Endpoint Type of meter that is currently under test.
Firmware Version
Module, HAN, and meter firmware versions for the endpoint that has been
successfully tested.
LPP Address The WAN and LAN address for the module of the meter tested.
Encryption Displays module encryption status as either enabled or disabled.
Routing Displays whether module routing is enabled or disabled.
Network ID
Network ID for the connected module in both decimal and hexadecimal
formats.
Take Out Point Address for the Take Out Point associated with the tested module.
Mode Settings <Current
Mode>
Displays the current mode of the module. Will be displayed as either Shop,
Field, or Installation.
Shop Mode is a special test mode, used while in manufacturing and
diagnostic troubleshooting, that is turned off at the end of the manufacturing
line. (not available for Concentrators)
Field Mode is for working with installed modules, and sets the module to
listen on the Network ID displayed on the Head End radio tab.
Installation Mode is a temporary state that initiates the first network
synchronization, and the auto registration process.
Meter
Meter Serial Number Serial number for the meter tested.
Meter ID Meter ID for the meter tested.
Disconnect Switch (only visible when the tested meter has an integrated switch)
Status Displays the status of the disconnect switch.
Switch Displays the switch state: either Connected or Disconnected.
Armed Status
Displays the armed state. May also display N/A, according to meter and
firmware version.
Utility Voltage Voltage that the utility is providing to the meter.
Customer Voltage
If service is connected, will be the same as the Utility Voltage. If
disconnected, will be near zero.
Table 3 - 4. Device Test tab(Continued)