Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr
46 98-1671 Rev AA User Guide
• Control byte 4 should be HEX 69.
• Control Byte 4 with RF Filter enabled and wide mode enabled should be HEX 29.
• Control Byte 4 with RF Filter disabled and wide mode enabled should be HEX 28.
• Max LAN Nodes could be set to 28 or 86 depending on your environment. If you are on a
deployed Normal meter network, 28 would be the best setting. If you are working in a
LARGE meter shop environment handling meter returns, sample testing, and First Article
Testing Max LAN Nodes value 56 (hex 86) would be best.
NOTE: Series IV radios appear in Command Center by default.
Authentication Server Connection
If the current instance of ETM is not connected to the Authentication Server, ETM will display
Work Offline in the status bar.
Figure 3 - 11. Login Validation
Connecting to a Collector
On the Connection tab, click the Collector Settings button to add a Collector. The Collector List
dialog box will appear.
Figure 3 - 12. Collector List Dialog
1. When adding a Collector to the Collector List, click the Add button. The Collector dialog will
appear.
Figure 3 - 13. Collector Dialog
2. Type a unique name into the Collector Name field.