User Manual
Table Of Contents
- 15-0028 - Exhibit Cover.pdf
- Elster A3 User Guide 98-1671.pdf
- Endpoint Overview
- Command Center Deployment/Configuration
- Deployment
- Tracking and Deployment
- Endpoint Configuration
- HAN Setup Process Overview
- HAN: Initialization
- Provisioning HAN Devices
- Remove HAN Devices
- Management and Troubleshooting
- Meter Swap Out Process using Decommission HAN
- Commission HAN Network for Channel Control
- Meter LCD Screen for ZigBee Alerts
- Confirm HAN Radio in Meter is Communicating or HAN is set-up
- Get information for a specific device
- Get Firmware version for the HAN radio
- Confirm that a HAN device can communicate with the meter
- Using Endpoint Testing Manager (ETM)
- Specifications
Landis+Gyr Chapter 2 - Command Center Deployment/Configuration
User Guide 98-1671 Rev AA 35
4. Click Send.
Meter LCD Screen for ZigBee Alerts
NOTE: After installation, the meter display will flash Z/B under the following conditions:
No network commissioned: The ZigBee module will request the time from the Gridstream radio
every 30 seconds after power up and every 15 minutes once it has received the time from the radio.
HAN Network is commissioned: When HAN is present, regardless of any devices present, the
ZigBee module will read the meter data every 30 seconds in anticipation of HAN devices needing
that information.
Confirm HAN Radio in Meter is Communicating or HAN is set-up
To confirm the existence of a HAN Network or to gather details on the HAN Network, issue the
HAN: Get Network Info command.
It will return the Channel and HAN ID.
Figure 2 - 26. HAN Network Info
Get information for a specific device
To confirm device details issue the HAN: Get Device Info command. It will return the MAC
Address, the Installation Code, and Device Type i.e: In Premise Display, Programmable Controllable
Thermostat.
Figure 2 - 27. HAN Device Info
Get Firmware version for the HAN radio
To confirm which firmware the HAN module in the meter is using issue the HAN: Get Firmware
command. This will return the ZigBee Firmware version number which will allow the user to figure
out if the meter is running the proper ZigBee Firmware.