User Manual

Table Of Contents
Chapter 2 - Command Center Deployment/Configuration Landis+Gyr
34 98-1671 Rev AA User Guide
Management and Troubleshooting
Meter Swap Out Process using Decommission HAN
For management and troubleshooting of the HAN Network and associated HAN devices, the
following commands can be used: Commission Network, Get Network Info, Get Device Info, Get
Firmware, and Ping.
NOTE: If a meter needs to be swapped out, the HAN must be decommissioned, or at very least, all
the HAN devices must be removed. Removing these devices will allow them to be re-provisioned
on the replacement meter.
Commission HAN Network for Channel Control
The HAN: Commission Network command is used to commission a HAN network with a specific
Channel and HAN ID. This command can be used to troubleshoot scenarios in which there may be
channel interference or spotty communication with a HAN device.
NOTE: A HAN Network will be automatically commissioned by provisioning a HAN device to a
meter if no HAN network is present. The automatic process will randomly assign the Channel from a
list of preferred channels as well as the HAN ID. See the section "Provisioning HAN Devices" for
details on adding/provisioning a HAN device to a meter.
1. On the Endpoint Information Window, select the Manage tab. Select HAN: Commission
Network from the Issue Commands drop-down menu. The user will need to select the
Channel and HAN ID.
Figure 2 - 25. Commission HAN Network
2. For Channel, choose Auto Select which will randomly select a SEP preferred channel
...or...
3. Select a specific channel 11-25.
HAN ID field will display the selected HAN ID.