Landis+Gyr Chapter 2 - Command Center Deployment/Configuration
User Guide 98-1671 Rev AA 31
status of Normal to a status of Configure. This status change indicates that the HAN initialization
process is underway. Once the meter status changes from Configure to Normal the HAN
initialization process is complete.
Figure 2 - 21. HAN: Initialization
Provisioning HAN Devices
Provisioning a HAN device (such as a display, smart thermostat, or direct load control unit) securely
joins a specific ZigBee-enabled HAN device with a specific meter so that they can communicate
across their meter's Home Area Network.
When the first HAN device for a meter is provisioned, a Home Area Network is automatically
commissioned. This involves Gridstream assigning a Channel (from a list of preferred channels) and
HAN ID. If there is a need to specifically assign the Channel and or the HAN ID, use the HAN:
Commission Network Command, as described under the Management and Troubleshooting section
below.
NOTE: Up to 5 devices may be provisioned to a single Non-Enhanced meter and up to 10 devices,
8 of which may be DRLC devices, for a single Enhanced Meter.
A device can be provisioned in two ways from Command Center: either 1) HAN Tab or 2) Manage
Tab on the Endpoint Information Window:
1. On the Endpoint Information Window, select the HAN tab.
Click the New button to display the new device fields shown below.