User Manual

Table Of Contents
Chapter 15 - Rockwell GPR-P Index Cover & GPR Install Landis+Gyr
86 98-1135 Rev AA Installation Guide
Figure 15 - 2. GPR Cover Gasket Tab and Cover Strain Relief Slot
Figure 15 - 3. GPR cover screws
3. Tighten the GPR cover screws to 13 inch-pounds (± 1 inch-pound).
A CAUTION: Check the index cover switch cable assembly for nicks, abrasions, or any damage
prior to installing the assembly onto the meter.
4. Install the GPR bracket onto the index cover so that the bracket slot straddles the cable strain
relief as shown in Figure 15 - 4.
5. Use the two 5/16-18 x 1.25" screws and tamper cups provided in the parts kit to attach the GPR
bracket onto the index cover as shown in Figure 15 - 4. Tighten the screws to between 15 and 20
inch-pounds, as shown in Figure 15 - 5.
Figure 15 - 4. Install GPR Bracket, Screws and Tamper Cups
6. Install tamper seals into the tamper cups as shown in Figure 15 - 7 and Figure 15 - 6.