User Manual

Table Of Contents
Chapter 14 - American GPR-P Index Cover & GPR Install Landis+Gyr
82 98-1135 Rev AA Installation Guide
Figure 14 - 2. GPR Cover Gasket Tab and Cover Strain Relief Slot
3. Tighten the screws to 13 inch-pounds (± 1 inch-pound).
Figure 14 - 3. GPR Cover Screws
4. Using two #12-24 x 1/2 inch screws (part# 22-0185), install the GPR-P Mini Switch cover
assembly as shown in the following photographs.
A CAUTION: Check the index cover switch cable assembly for nicks, abrasions, or any damage
prior to installing the assembly onto the meter.
5. Install a new index cover gasket as required. Tighten the screws to 20 inch-pounds (± 5 inch-
pounds.
Figure 14 - 4. Tighten Front and Rear Cover Screws to 20 in-lbs (± 5 in-lbs)
NOTE: Photos are for illustrative purposes only. Torque driver not shown in photos.
U WARNING: Take care not to pinch the index cover switch cable assembly in any way,
especially during the following installation steps:
During index cover and cable assembly installation onto the meter.