Cover & GPR Install
GPR Direction
The GPR must face away from nearby walls and toward the nearest MCC or Concentrator, and
should be installed in a location unobstructed by gas pipes. Mounting options are shown and
described in Appendix A
, American Changing GPR Orientation.
GPR Mounting
1. Arrange the GPR Pulse Input and Battery Interface cables as shown in Figure 14 - 1. The cables
must not interfere with or block the GPR antenna.
A CAUTION: The GPR Pulse Interface cable must be inserted into the GPR enclosure strain
relief slot as shown. The shrink tubing on the cable must be inserted into the strain relief slot.
Figure 14 - 1. Pulse Interface Cable’s Shrink Tubing Must Route Through GPR Strain Relief Slot
2. Install the GPR cover using the four security Torx screws included with the GPR. The cover
must be installed with the gasket tab inserted into the strain relief slot located at the bottom left
corner of the GPR enclosure as shown in the following photos.