User Manual

Table Of Contents
Landis+Gyr Chapter 11 - Rockwell GPR Configuration and Waterproofing
Installation Guide 98-1135 Rev AA 69
Figure 11 - 4. Apply the Compound to the GPR Pulse Input Connector
2. Force the compound between the connector pins with a cotton tipped swab or other suitable
applicator as shown in Figure 11 - 8.
Figure 11 - 5. Force the Compound between Connector Pins
3. Liberally apply the compound to the connectors of the GPR Pulse Input and Battery Interface
cables. Force the compound into ALL holes and cover ALL electrical contacts, as shown in the
following photos.
NOTE: The following photos show representative cables to illustrate compound application.
Figure 11 - 6. Apply the Compound to GPR Cable Connectors: Cover All Contacts
4. First, install the GPR Pulse Input cable, and then the Battery Interface cable, onto the GPR
circuit board connectors as shown in Figure 11 - 10.
U WARNING: The GPR Pulse Input cable MUST be installed prior to installing the Battery cable.