Installation Guide 98-1135 Rev AA 49
Installing The Index
1. Install the index and frame assembly onto the meter.
2. Align the index drive shaft arm with the meter as shown in the next figure.
3. Using the 5/16-18 x 3/8” index frame screws that were set aside at the beginning of this
procedure, tighten the screws to 18 foot-pounds. ± 2 foot-pounds.
NOTE: For proper meter operation, the index frame screw tabs should be about 90 degrees
(perpendicular) to the upper portion of the frame containing the index.
Figure 7 - 5. Index Drive Shaft Arm Alignment
If the index must be replaced or if the index has been removed from the frame, install the index
to the frame and tighten the 8-32 x 3/16 inch screws to 10.5 inch-pounds (± 1.5 inch-pound).
A CAUTION: The index MUST be installed with the mounting bracket inside the index back
plate, as shown in the following photograph.