User Manual

Table Of Contents
Chapter 6 - American Mini Switch Kit Installation Landis+Gyr
40 98-1135 Rev AA Installation Guide
Index drive mechanism does not rotate easily.
U WARNING:
The 2-Piece magnetic pulse wheel (29-1312) must be used with metal pointer indexes.
The 2/3 magnetic pulse wheel (40-1531) must be used on plastic pointer indexes.
Installing 2-Piece Magnetic Pulse Wheels on Metal Pointer Indexes
U WARNING: For 2-piece magnetic pulse wheels with alignment slots, the wheels must be
installed so that the alignment slots on each wheel half are on top as shown in the next
figure.
Figure 6 - 3. Where Alignment Slots Are Present On 2-Piece Magnetic Pulse Wheels, The Slots
Must Be Installed On Top
NOTE: For wheels WITHOUT alignment slots, there is no top or bottom, and there is no special
consideration regards dial wheel assembly.
1. Insert screws into the notched pulse wheel half.
Figure 6 - 4. Magnetic Pulse Wheel Half with Screws Inserted
2. Rotate the index drive mechanism so that the metal proving/test pointer is in an upward
direction.
NOTE: For wheels WITHOUT alignment slots, there is no top or bottom, and there is no special
consideration regards dial wheel assembly.