User Manual

Table Of Contents
Chapter 3 - Rockwell Index Cover & Gas Module Removal Landis+Gyr
28 98-1135 Rev AA Installation Guide
NOTE: There are two types of Rockwell Commercial index covers. Shown at left in Figure 3 - 3 is
the Center Dial Mount and at right is the Offset Dial Mount. Both types may be removed from the
meter in the same manner as shown in the next illustration.
Figure 3 - 4. Remove Module Bracket Tamper Seals, Screws, and Gas Module Assembly
3. Remove the 5/16-18 x 3/8" index frame screws and index mounting frame assembly from the
meter. Set the screws aside for later use.
A CAUTION: DO NOT remove the index from the mounting frame unless the frame or index is
damaged.
For proper meter operation, the frame screw tabs should be approximately 90 degrees
(perpendicular) to the upper portion of the frame containing the index.
Figure 3 - 5. Index Frame Screws and Frame Tabs
Figure 3 - 6. Commercial Module Cover Removed
Module Cover Tamper Seal
Location
Serial/Power
Connector