User Manual

Table Of Contents
Landis+Gyr Chapter 2 - American Index Cover & Gas Module Removal
Installation Guide 98-1135 Rev AA 25
Figure 2 - 6. Remove Index Cover and Module Bracket Tamper Seals
C. Remove the index cover fasteners. If needed, use a 5/16 inch combination wrench to loosen
the index cover front bolt.
Figure 2 - 7. Remove Index Cover Fasteners
D. Remove the module bracket fasteners and carefully disconnect the module and index cover
assembly from the meter.
E. If the original gasket is damaged or cannot be reused, replace the index cover gasket. A
scraper and wire brush may be required to remove leftover gasket material.
Figure 2 - 8. Cover Gasket and Base Plate with Optional Tamper Cup & Seal
Remove Tamper Seals