User Manual

Table Of Contents
Appendix B - Rockwell Changing GPR Orientation Landis+Gyr
104 98-1135 Rev AA Installation Guide
Figure B - 3. GPR Bracket Disassembly
2. Determine the appropriate GPR direction.
3. Install the two screws and lock washers. Tighten the screws to 30 inch-pounds (+0 / -2 inch-
pound).
A CAUTION: If the meter’s pipe route prevents installing the GPR as described in this manual,
the GPR may be mounted in a remote location away from the meter, such as on a wall or a
gas pipe. The maximum cable length between the Index Cover Assembly and GPR must not
exceed 200 feet.
In a remote GPR Mounting environment, Pipe Bracket Kit 45-0080 may be used to install the
GPR on suitable plumbing pipes. Remote GPR mounting is beyond the scope of this manual.