User Manual
Landis+Gyr
Chapter 5 - RF Filter and Battery Replacement Kits
Network Concentrator User and Installation Guide 98-1013 Rev AF 58
4. Remove all eight pan head screws and the battery pack.
Figure
5 - 10.
Sample Pan Head Screw
Location
5. Place the new battery pack in the enclosure base and secure it with all eight pan head screws.
6. Torque the screws to 8 ±.5 in-lbs.
7. Connect the battery cable.
8. Replace enclosure gasket (PN 106555-000) with a new gasket. Do not re-use the old gasket.
9. Attach the enclosure lid to the enclosure base.
Take care to not pinch the battery cable between the base and the lid.
Pinching
the cable can short the battery and result in a hazardous
condition.
10. Secure with all six bolts, nuts, washer-flats, and washers.
11. Torque bolts to 45 ±.5 in-lbs.
12. Affix the new battery date label to the outside of the enclosure.
Figure
5 - 11.
New battery date label affixed
to
concentrator
enclosure