Landis+Gyr Chapter 6 - Performing System Upgrades
Concentrator User and Installation Guide 98-1031 Rev AA 59
Concentrator Verification
Verify that the concentrator has booted up with the latest firmware.
1. Open a command window on your PC.
2. Use your administrative credentials to login as control user.
3. Type
oms -op getattr -class mcc -mccad 30000.1 -attrnm fWRevision -
remote
Bankcopy MCC
The Concentrator can send image data from B to memory location A. The Concentrator must be
running from location B to ensure the operation is successful.
Copy the image by typing
./utlICDownload - mccad 3000.1 -session 2 -bankcopy
Restarting a Download
You can interrupt a download to substitute a newer file than the one currently being downloaded.
1. Suspend the client program by typing
Control + C
2. Send a disconnect command. At the prompt type
utlICDownload -mccad 30000.1 -session 2 -disconnect
3. Hot boot the concentrator.
Upgrading Concentrator Firmware Directly via Cable
You can connect a cable to the concentrator and upgrade interior components via direct cable
connection or through a wired intranet or hub. Following are direct upgrade procedures. To perform
these tasks you need:
• a concentrator
• a serial cable
• an AC power cable
• an intranet connection
• a hub (optional)
• an upgrade CD or link that includes rom.bin and image.bin files
• Hyperterminal
• a command prompt
• Network Configuration Manager