Landis+Gyr Chapter 4 - Concentrator Installation
Series IV Concentrator U and I Guide 98-1031 Rev AA 41
8. Attach the right-angle end of the cable to the top of the LAN antennas.
Figure 4 - 11. Attaching right-angle end of cable
9. With the mounting kit, affix the concentrator and two brackets sandwiched on the pole down
from the light arm using the supplied hardware.
Figure 4 - 12. Concentrator mounted
10. Attach the AC power cable to the concentrator using one of the power cable options. Leave slack
in the cable to form a drip loop.
If using the 105704-000, 105704-001, 105704-002, or 105704-003 cables, the
end of the cable opposite the connector (the unterminated end) must be
installed in a junction box or other suitable enclosure.
Leaving the end of the cable exposed may allow water to migrate into the
cable and into the Concentrator.
See Appendix G
for power cable installation procedures and details.