Page 8 of 11
MCC860 EEPROM Configuration Menu
d Display all configuration items a page at a time
x Display all configuration items with no paging
D Display only new items
s Set specific items (choose from paged list)
n Set specific items by name or id number
a Interactively set all items (prompt for each one)
A Interactively set new items
e Interactively set all out-of-range items
E Interactively set out-of-range new items
r Set all items to defaults (no prompting)
R Set new items to defaults
f Set all out-of-range items to defaults
F Set out-of-range new items to defaults
S Save EEPROM cache to NAND File
G Get the EEPROM params from Nand
q Quit
Select option (? for menu): q
You have changed parameters which require an MCC Hot Boot.
Are you ready to reset? (y/n): y
The following comes back up after the MCC resets
Cellnet
MicroCell Controller
14.0.06_860,[v14035-mcc-p14.17-cmgcs@pagoda],01-17-08@17:05:16
Warm starting all MCC860 tasks...
WAST DOGY PCMT PTST SCCT PFMT DIAG RSTP
DLTT ODES OTBS CALA TOUA OD1A TOMM MLPA
ASAP RFLA RDSA RSTT DTTA RCAT TIME MCCA
MCAA OFTT EVST LSTA TOAT STMT PFTT SRAT
DTOA BLTR
34 tasks started, recovering ODE database...,
1206038499,12 Reset flag RESET_CONFIG_CHANGE
1206038499,12 [ BANK B ] Reset msg "EEPROM changes require Hot Boot"
MCC860 Waiting for Recovery End