User's Manual

SOP Utilinet Concentrator Installation
XX-XXXX, Rev: 01
Page 16 of 18
© Cellnet 2006. All rights reserved.
5.4.2 Wood utility pole
1. Using mounting kit 45-1035 mount Bracket 28-1079 to wood pole using two MCC
mounting bolts (D/A Bolts) with washer and nut.
Fig. 3
2. Attach BATTERY PACK (26-1136) to bracket using (4) carriage bolts (101887-350).
Secure with nuts (101983-025) and washers (22-0421).
3. Attach Concentrator (26-1129) to bracket, being aware to face the military connectors
toward the pole as there are weep holes in the event of condensation. Using (4) carriage
bolts (101887-350). Secure with nuts (101983-025) and washers (22-0421).
4. Connect the Battery pack to the Concentrator with battery cable (19-1125).
5. Using either 19-2200 or a locally created cable connect antennas 01-1239 and ground
planes to Concentrator and bracket (28-1079).