6 \98-9103 Rev AA Data Sheet
Communication Module Specifications
Table -1. Gridstream RF S4e Communications Module Specifications
Category Specification Value or Range
Compatible
Meters
Landis+Gyr S4e Supported
Meter Forms
Form Class Form Class
3S 20 16SE 320
5S/45S 20 16/15K 480
6S/36S 20
9S/8S 20
2S 200
12S 200
16S/15S 200
25S 200
12SE 320
Electrical
Voltage 10.5-13.5V (from the meter’s power supply)
Power
Max: 2.5W
Typic a l : 0 .5 W
RF 900 MHz
Output Power +26 dBm +/-1 dBm
Adjacent Channel Power 39 dBc Nominal (9600 bps)
Transmit Frequency 902 to 928 MHz ISM unlicensed (FCC Part 15)
Communication Protocol Gridstream Protocol for Command Center
Receive Sensitivity -108 dBm minimum
RF ZigBee
Output Power +20 dBm +/-1
Adjacent Channel Power 40 dBc Minimum
Transmit Frequency 2405-2480 MHz
Communication Protocol ZigBee Protocol
Receive Sensitivity -104 dBm minimum
Standards
Compliance
FCC Title 47 CFR Part 15
Radiated and Conducted Emissions (incl.
intentional radiators)
IEC 61000 4-2,3,4,5,11,12 Electromagnetic Compatibility
ANSI C12.19 Compatible with Utility Industry End Device Tables
ANSI C12.20
National Standard for Electricity Meters - 0.2 and
0.5 Accuracy Classes
ANSI C12.1 Code for Electricity Metering
ANSI C37.90.1 (1989) Standard Surge Withstand Capability (SWC) Tests
ANSI C12.22
Transport of ANSI C12.19 Over Network
Transmissions
Draft 5.8.13