Data Sheet
Table Of Contents
Cellnet+Hunt FOCUS Universal RF Endpoint Data Sheet
Data Sheet PUBS-0762-0001 Rev A 3
Specifications
Table 1. FOCUS Universal RF Endpoint Specifications
Category Specification Value or Range
Compatible
Meters
Meter Type Landis+Gyr FOCUS AL
Supported Meter Forms
120V FASY-0762-0001 240V FASY-0762-0002
For
m
Clas
s
L+G Part Number For
m
Clas
s
L+G Part Number
1S 100 EA0000T0-
QQQQ*
2S 200 EA1100T0-
QQQQ*
3S 20 EA0G00T0-
QQQQ*
2SE 320 EA1400T0-
QQQQ*
12S 200 EA01C0T0-
QQQQ*
2K 480 EA1600T0-
QQQQ*
25S 200
EA0A00T0-
QQQQ*
3S 20 EA0H00T0-
QQQQ*
4S 20 EA0J00T0-QQQQ*
NOTE: The last four digits of the Landis+Gyr part number identify a
specific customer feature set including custom name plate,
programming and RKAs.
Electrical
Voltage 120/240V (depending on meter form)
Power
Max: 2.2W (1.2W meter, 1W transceiver)
Typical: 1.2W (.7W meter, .5W transceiver)
RF
Output Power +26 dBm +/-2 dBm
Adjacent Channel Power +50 dBc Nominal
Transmit Frequency 902 to 928 MHz ISM unlicensed (FCC Part 15)
Communication Protocol Stat RF MESH Protocol
Receive Sensitivity -108 dBm minimum
Standards
Compliance
FCC Title 47 CFR Part 15 Radiated and Conducted Emissions (incl. intentional radiators)
IEC 61000 4-2,3,4,5,11,12 Electromagnetic Compatibility
ANSI C12.19 Compatible with Utility Industry End Device Tables
ANSI C12.20 National Standard for Electricity Meters - 0.2 and 0.5 Accuracy Classes
ANSI C12.21 Code for Electricity Metering
ANSI C37.90.1 (1989) Standard Surge Withstand Capability (SWC) Tests