User's Manual
Cellnet+Hunt StatSignal Multi-Utility Residential Endpoint Data Sheet
StatSignal PUBS-0710-0002 Rev A 3
• Increase the separation between the equipment and receiver.
• Consult Cellnet+Hunt or an experienced radio/TC technician for help.
Specifications
Table 1. StatSignal Multi-Utility Residential Endpoint Specifications
Category Specification Value or Range
Compatible
Meters
American Gas Meters Invensys/Equimeter Actaris/Schlumberger/Sprague
Domestic meters, circular
read and direct read indi-
ces.
For sizes 175 and 250CFH
Models.
Domestic meters, circular
read R-275 index.
Domestic meters, direct read
and circular read indices.
For sizes 240, 250 and 400
CFH Models.
Electrical
Voltage 3.6 vdc Battery Powered
Power
Transmit Sleep
450mA +/- 15mA <10uA
RF
Output Power +23 dBm +/- 2dB
Adjacent Channel Power +50dBc Nominal
Transmit Frequency 910 to 928 MHz ISM unlicensed (FCC Part 15)
Communication Protocol StatSignal RF MESH Protocol
Receive Sensitivity -108 dBm minimum (-110 dBm typical)
Standards
Compliance
FCC Title 47 CFR Part 15 Radiated and Conducted Emissions (incl. intentional radiators)
ANSI /IPC-A-610 Class 2 Workmanship for electronics assembly
ETL Class 1 Div 2 Group D
Environmental
General Environmental Outdoor, rain-protected, sunlight-exposed
Operating Temperature
Range
-40 to +85
Humidity 0 to 95% relative humidity, non-condensing
Mechanical
Size 4 5/8”W x 4 5/8”L x 1 7/8”H inches, typical
Weight 4.2 ounces (119.2g), typical
Contact Information:
Technical Support:
1-888-390-5733
Internet:
www.cellnethunt.com
Fax
1-218-562-5530
E-mail:
support@cellnethunt.com