Operation Manual
LANCOM GS-2124
쮿 Kapitel 5: Operation of CLI Management (englisch)
261
DE
<timezone>: -12,-11…,0,1…,13
왏 Example:
GS-2124L(time)# set ntp clock.via.net 8
Synchronizing...(1)
Synchronization success
쮿 show
왏 Syntax:
show
왏 Description:
To show the time configuration, including “Current Time”, “NTP Server”,”
Timezone”,
” Daylight Saving”,” Daylight Saving Start” and “Daylight Saving End”
왏 Argument:
None.
왏 Possible value:
None.
왏 Example:
GS-2124L(time)# show
Current Time: Thu Thu 14 15:04:03 2005
NTP Server: 209.81.9.7
Timezone: GMT+8:00
Day light Saving: 0 Hours
Day light Saving Start: Mth: 1 Day: 1 Hour: 0
Day light Saving End : Mth: 1 Day: 1 Hour: 0
GS-2124L(time)#
° trunk
쮿 del trunk
왏 Syntax:
del trunk <port-range>
왏 Description:
To delete the trunking port.