Installation guide

Management
Option to choose if an uploaded certificate or the default certificate is used by the HTTPS serverHTTPS Server
Access rights (read/write) over WAN or (W)LAN can be set up separately (Telnet/SSL, SSH, SNMP, HTTPS/HTTP), access control listSecurity
Scripting function for batch-programming of all command-line parameters and for transferring (partial) configurations, irrespective of software
versions and device types, incl. test mode for parameter changes. Utilization of timed control (CRON) or connection establishment and termination
to run scripts for automation. Scripts can send e-mails with various command line outputs as attachments
Scripting
LoadFirmware, LoadConfig and LoadScript can be executed conditionally in case certain requirements are met. For example, the command
LoadFirmware could be executed on a daily basis and check each time if the current firmware is up to date or if a new version is available. In
addition, LoadFile allows the upload of files including certificates and secured PKCS#12 containers
Load commands
SNMP management via SNMPv2, private MIB exportable by WEBconfig, MIB IISNMP
Scheduled control of parameters and actions with CRON serviceTimed control
Extensive LOG and TRACE options, PING and TRACEROUTE for checking connections, LANmonitor status display, internal logging buffer for SYSLOG
and firewall events, monitor mode for Ethernet ports
Diagnosis
Supported by all LANCOM WLAN Controller (separate optional hardware equipment for installation, optimization, operating and monitoring of
WLAN networks, except for P2P connections)
LANCOM WLAN Controller
Statistics
Extensive Ethernet, IP and DNS statistics; SYSLOG error counterStatistics
Connection time, online time, transfer volumes per station. Snapshot function for regular read-out of values at the end of a billing period. Timed
(CRON) command to reset all counters at once
Accounting
Accounting information exportable via LANmonitor and SYSLOGExport
Hardware
Via Power over Ethernet (max. distance between access point, injector and switch 50 m), 1 x PoE Injector supplied*Power supply
1 x 48 V DC with optional 48V cable (not included in delivery)Power supply
-25° C to +50° C at 95% max. humidity (non condensing)Environment
235 mm x 210 mm x 80 mm (W x H x D), 3.4 kg, robust metal housing, IP 66 protection rating, ready for wall and pole mounting, 6 LEDs for status
display
Housing
37 Watt when heating is active, 27 Watt when heating is not activePower consumption (max)
PoE operates with the supplied PoE adapter only*) Note
Declarations of conformity
EN 60950-1:2006/AC:2011, EN 301 489-1 V1.9.2, EN 301 489-17 V2.1.1CE
ETS 300 3282.4 GHz WLAN
EN 301 893 version 1.7.1, EN 302 502 (BFWA)5 GHz WLAN
Certifications notified in Germany, Belgium, Netherlands, Luxembourg, Austria, Switzerland, UK, Italy, Spain, France, Portugal, Czech Republic,
Denmark
Notifications
Package content
Hardware Overview (EN, DE), Installation Guide (DE/EN/FR/ES/IT/PT/NL)Manual
Data medium with firmware, management software (LANconfig, LANmonitor, WLANmonitor) and documentationCD/DVD
Water-resistant, UV-resistant Ethernet PoE cable with water-resistant screw connector, 15mCable
AirLancer Adapter NP-NP 25 cm, connector for external LANCOM outdoor antennasCable
Four 3 dBi dipole dual-band antennasAntenna
Via Power over Ethernet*, 1 x Gigabit High Power PoE (50W/56V) Injector suppliedPower supply unit
Power over Etherner operates with the supplied PoE adapter only*) Note
Support
3 years Support via Hotline and Internet KnowledgeBaseWarranty
Regular free updates (LCOS operating system and LANCOM Management System) via InternetSoftware updates
LANCOM OAP-382
Features as of: LCOS 8.80