System information
LANCOM ES-2126+ und LANCOM ES-2126P
쮿 Chapter 5: Operation of CLI Management
167
EN
쮿 set timer
왏 Syntax:
set timer <range> <join> <leave> <leaveall>
왏 Description:
To set gvrp join time, leave time, and leaveall time for each port.
왏 Argument:
<range> : port range, syntax 1,5-7, available from 1 to 26
<join>: join timer, available from 20 to 100
<leave>: leave timer, available from 60 to 300
<leaveall>: leaveall timer, available from 1000 to 5000
Leave Time must equal double Join Time at least.
왏 Possible value:
<range> : 1 to 26
<join>: 20 to 100
<leave>: 60 to 300
<leaveall>: 1000 to 5000
왏 Example:
PSES-2126C(gvrp)# set timer 2-8 25 80 2000
쮿 show config
왏 Syntax:
show config
왏 Description:
To display the gvrp configuration.
왏 Argument:
None.
왏 Possible value:
None.
왏 Example:
PSES-2126C(gvrp)# show config
GVRP state: Disable
Port Join Time Leave Time LeaveAll Time Applicant
Registrar Restricted