User Manual
7. SPECIFICATIONS
7 SPECIFICATIONS
AC Line Input: 115 volts 10%, 50/60Hz, 14 amperes or
230 volts 10%, 50/60 Hz, 7 amperes
(selectable inside unit)
DC Discharge Current: Capacity
0 - 50 amperes adjustable current
Accuracy
2% from discharge initiation to cut-off
Constant Current Capacity 0 - 25 amperes adjustable, 35 volt limit
Charge Mode:
Accuracy 2% from charge initiation to completion
Constant Potential Setting Selectable 14.5/28.6 volts, 25 ampere limit
Charge Mode:
Accuracy 2% from charge initiation to completion
Timer: Setting Adjustable from 0 to 999.9 units
Units
Selectable on front of timer from 0.1 to 999.9
Accuracy
1.0%
Digital Meter Accuracy: Voltmeter 0.2 volts
Ammeter 0.2 amperes
Cooling: Fan cooled
Housing: Compact transit case
Outer Dimensions: Height 14 in. (356 mm)
Depth
15 in. (381 mm)
Width
10 ¼ in. (260 mm)
AC Line Cord:
AWG 14 3 wire grounded
6 ft long with 115 volt 15 ampere plug
User required to change to 230 volt plug
DC Discharge Cable: 4 ft Terminal w/Quick Disconnect Adaptor
Weight: Net 53 lbs. (24.1 kg)
Shipping 58 lbs. (26.3 kg)
Fuses: AC line 20A/250V, type MDA 1 ¼ x ¼
Charge line 40A/32V, type MDL 1 ¼ x ¼
Discharge 70A/32V, type Lfuse 0498070
Adaptors Included: Alligator Clip Connector, 24V Aircraft Battery Connector,
and Ring Terminal Connector
CA-1550 CHARGER / ANALYZER - OPERATING MANUAL V1.2 Page 36