TechnicalSpecifications continued…
Safety Features
Collection Vessels:
Hinged shrouds are installed over the collection vessels, covering the seal of the lid of the collection
vessel, to prevent accidental splashes and spraying of an operator.
Redundant system to the collection vessel lid seal
Non-return valve (check valve) is installed between the discharge of the collection vessel and the
fryer to prevent oil from returning from the fryer into the vessels.
Two manual isolation ball valves, one on the inlet to collection vessel and one on the discharge or
return of the vessel, to completely shut-off the flow of oil to the vessel. One set of valves on each
vessel.
Redundant system to the three-way valve and non-return valves
A mechanical lever system to tie together the operation (opening and closing) of the two manual
isolation ball valves. When the valves are open, the position of the handle of the lever system
prevents the shroud from being opened. One lever system on each vessel.
An analog temperature gauge (thermometers) installed on the outside of the fines collection vessel
for visual inspection by the operator prior to opening vessel. One gauge on each vessel.
Pipe System/Manifold:
All piping connections, other than to the separator, are made with sanitary clamps