Owner manual
LAKOSCookingOilFrySafeSystems
17
Start-Up Procedures and Operation
continued…
The above sequence will switch from vessel #2 to vessel #1. To switch back to vessel #2, use the same
order with the appropriate valves.
Clean Collection Vessel
Collection vessel cleaning is to be done after Switch Fines Vessel Procedures have been followed.
1. Check vessel temperature (100ºF is Safe).
2. Blow-down valve opened for 1 minute at 60psi (blow-down can occur before vessel
has cooled).
3. Blow-down valve closed.
4. Check vessel gauges (0 psi is safe).
5. Close isolation handle when temperature and pressure is safe.
6. Raise splash guard.
7. Open t-bolt closure slowly.
8. Remove and clean baskets (hot water only no scraping).
9. Reinstall clean baskets, close t-bolt closure.
10. Lower splash guard.
11. Open isolation valve (vessel ready for service).
The above procedure will ready vessel for next switch of the vessels. The above instructions are to be
used with the appropriate valves illustrated on the manual system on page 14.