Owner manual

LAKOSCookingOilFrySafeSystems
12
System Installation
Assemble the system into place and level using the leveling devices on the underside of the support
structure. The system does not need to be anchored to a concrete floor or foundation.
A piping by-pass, as diagramed on the LAKOS system installation drawing on page 14, is good practice,
in case the LAKOS Cooking Oil FrySafe System needs to be removed from service.
If necessary, disassemble the mated flanges at the collection chamber and barrel of the separator and
the nuts on the separator support ring to position the inlet in the required orientation.
If necessary, disassemble the mated flanges at the top of the separator to position the separator’s
discharge to the required orientation.
Plumb the inlet pipe to the provided ANSI flange on the separator, to the discharge of the fryer pump.
Refer to the LAKOS system drawing in this section.
Plumb the discharge pipe to the provided ANSI flange on the separator returning to the heat exchanger
or fryer. Refer to LAKOS system drawing in this section.
Warning: The inlet pipe of the separator is the horizontal pipe at the top of
the separator and the discharge pipe of the separator is the vertical pipe at
the top of the separator. Misplumbing the separator will prevent the
separator from operating correctly.
Warning: Inlet and outlet piping to and from the separator must be
supported to avoid any possible strain to the unit’s flanged connections.
The use of pipe supports, clamps, and hangers is required.