SLOW(32KHZ)CLOCKSOURCEREQUIREMENTS
Theslowclockisalwayssuppliedfromanexternalsource.ItisinputontheSLOW_CLKpin,andcanbeadigitalsignalinthe
rangeofVIOonly.ForslowclockfrequencyandaccuracyrefertoTable19.Theexternalslowclockmustbestablebefore
thesystemexitsfromshutdownmode.
Parameter[1] Condition Symbol Min Typ Max Unit
Inputslowclockfrequency 32768 Hz
Inputslowclockaccuracy WLAN,B
T
+/‐250 ppm
InputtransitiontimeT
r
/T
f
–10%to90% T
r
/T
f
100ns
Frequencyinputdutycycle 30 50 70 %
Inputvoltagelimits
Squarewave,
DCcoupled
VIH
0.65xVDDS VDDS V
peak
VIL 0 0.35xVDDS
Inputimpedance 1 MW
Inputcapacitance 5pF
Riseandfalltime 100ns
Phasenoise 1kHz ‐125 dBc/Hz
[1]Slowclockisafailsafeinput