User Manual
TiWi-BLE TRANSCEIVER MODULE
DATASHEET
The information in this document is subject to change without notice.
330-0087-R2.1 Copyright © 2011-2013 LS Research, LLC Page 9 of 40
ELECTRICAL SPECIFICATIONS
The majority of these characteristics are based on controlling and conditioning the tests using the TiWi-
BLE control software application. Other control conditions may require these values to be re-
characterized by the customer.
Absolute Maximum Ratings
Parameter
Min
Max
Unit
Power supply voltage (VBAT)
(4)(5)
-0.5
+5.5
V
Digital supply voltage (VIO)
-0.5
2.1
V
Voltage on any GPIO
-0.5
VIO + 0.5
V
Voltage on any Analog Pins
(3)
-0.5
2.1
V
RF input power, antenna port
+10
dBm
Operating temperature
(6)
-40
+85
ºC
Storage temperature
-55
+125
ºC
1. Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device and are not
covered by the warranty. These are stress ratings only and functional operation of the device at these or any other
conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-
maximum-rated conditions for extended periods may affect device reliability.
2. All parameters are measured as follows unless stated otherwise: VDD_IN=1.8V, VDDIO_1.8V=1.8V,
VDD_LDO_CLASS1P5=3.6V
3. Analog pins: XTALP, XTALM, RFIOBT, DRPWRXBM, DRPWRXBP, DRPWTXB, and also FMRFINP, FMRFINM,
FMRFINM, FMAUDLIN, FMAUDRIN, FMAUDLOUT, FMAUDROUT
4. The following signals are from the VBAT group, PMS_VBAT and VDD_LDO_CLASS1P5 (if BT class 1.5 direct VBAT is
used).
5. Maximum allowed depends on accumulated time at that voltage; 4.8V for 7 years lifetime, 5.5V for 6 hours cumulative.
6. The device can be reliably operated for 5,000 active-WLAN cumulative hours at T
A
of 85
o
C.
Table 4 Absolute Maximum Ratings
Recommended Operating Conditions
Parameter
Min
Typ
Max
Unit
V
BAT
3.0
3.6
4.8
V
VIO
1.62
1.8
1.92
V
V
IH
0.65 x VIO
-
VIO
V
V
IL
0
-
0.35 x VIO
V
V
OH
@ 4, 8 mA
VIO - 0.45
-
VIO
V
V
OL
@ 4, 8 mA
0
-
0.45
V
Ambient temperature range
-40
25
85
ºC
Table 5 Recommended Operating Conditions