User's Manual

SSD50NBT
Hardware Integration Guide
Embedded Wireless Solutions Support Center:
http://ews-support.lairdtech.com
www.lairdtech.com/bluetooth
30
© Copyright 2015 Laird. All Rights Reserved
Americas: +1-800-492-2320
Europe: +44-1628-858-940
Hong Kong: +852 2923 0610
If there are other radios or transmitters located on the device (such as a Bluetooth radio), place the
devices as far apart from each other as possible. Also, make sure there are at least 25 dB isolation
between Bluetooth antenna and Wi-Fi antenna.
Ensure that there is the maximum allowable spacing separating the antenna connectors on the Laird radio
from the antenna. In addition, do not place antennas directly above or directly below the radio.
Laird recommends the use of a double shielded cable for the connection between the radio and the
antenna elements.
Be sure to put the capacitor on the power pin as close as possible to reduce the radiation issue.
Use proper electro-static-discharge (ESD) procedures when installing the Laird radio module.
In order to get maximum throughput when operate at MIMO 2x2, two antennas with at least 25 dB
isolation is recommended.
To avoid negatively impacting TX power and receiver sensitivity, do no cover the antennas with metallic
objects or components.
RECOMMENDED STORAGE, HANDLING, BAKING, AND REFLOW PROFILE
Required Storage Conditions
Prior to Opening the Dry Packing
The following are required storage conditions prior to opening the dry packing:
Normal temperature: 5~40
Normal humidity: 80% (Relative humidity) or less
Storage period: One year or less
Note: Humidity means Relative Humidity.
After Opening the Dry Packing
The following are required storage conditions after opening the dry packing (to prevent moisture absorption):
Storage conditions for one-time soldering:
Temperature: 5~25
Humidity: 60% or less
Period: 48 hours or less after opening
Storage conditions for two-time soldering
Storage conditions following opening and prior to performing the 1
st
reflow:
Temperature: 5~25
Humidity: 60% or less
Period: 48 hours or less after opening
Storage conditions following completion of the 1
st
reflow and prior to performing the 2
nd
reflow
Temperature: 5~25
Humidity: 60% or less
Period: 48 hours or less after completion of the 1
st
reflow