3.3 Recommended Application Connections - AVRISP
Figure 2 shows the minimum circuit connections required for the SiFLEX module, if
programming with the AVRISP mkII. The AVRISP mkII can only be used for
programming; in-circuit debugging must be done via JTAG. This circuit is identical to the
one in Figure 1, with the exception of the connection for the AVRISP mkII.
(Optional LEDs)
(Optional buttons)
26 VCC UART TX 35
UART RX 36
PF3 27
13 JTAG/PDI/JRST
PF2 28
14 nRESET
PF1 29
PE5 31
44 GND PF0 30
ISP Header
SiFLEX Module
TX
RX
Module Reset
VCC
GND
USER1
Host
470 Ω
10 kΩ
47 nF
470 Ω
470 Ω
USER2
47 nF
10 kΩ
Green
Red
Yellow
21
43
65
RESET
1 kΩ
(Optional button)
1 kΩ
Figure 2 Sample Application Circuit with AVRISP