User Manual
PRO-FLEX SERIES TRANSCEIVER MODULES
HOST PROTOCOL GUIDE
The information in this document is subject to change without notice.
Confirm the data is current by downloading the latest revision of this document from www.lsr.com.
PFLX-UG-0001-00-09 Copyright © 2009 LS Research, LLC Page 9 of 37
3.2 Host Protocol Message Definitions
Host to
Module
Module
to Host
Allow
Remote
Message
Length
Payload
Length
Payload
Name
Description
3.2.1 Query Firmware Version
0x01 -
X
5 -
- 0x81 12+n
1
Module
Identifier
Identifies this module as a ProFlex module
(0x02).
1
Version
Major
Version major number.
1
Version
Minor
Version minor number.
1
Version
Month
Version month (1 - 12).
1 Version Day Version day (1 - 31).
1 Version Year Version year (0 - 99).
1
Version
String Length
Length of version string (0 - 32 bytes).
n
Version
String
Version string (0 - 32 bytes in length).
3.2.2 Set PAN ID
0x02 -
7 2 PAN ID
Two byte PAN ID (LSB to MSB) of the
network this transceiver should operate on.
- 0x82 5 -
3.2.3 Query PAN ID
0x03 -
5 -
- 0x83 7 2 PAN ID
Two byte PAN ID (LSB to MSB) of the
network this transceiver should operate on.