User's Manual

Enhanced Class 1 Bluetooth v2.1 Module
User’s Guide
Americas: +1-800-492-2320 Option 2
Europe: +44-1628-858-940
Hong Kong: +852-2923-0610
www.lairdtech.com/wireless
67
CONN-GUIDE-BT740_v0.2
INFOTYPE = CCL STACK BRANCH VERSION (241 0xF1)
Offset
Field Name
Range
Comments
6..7
Stack Branch Version
E.g. 1234
Branch Version of CCL stack
INFOTYPE = CCL STACK VENA VERSION (248 0xF8)
Offset
Field Name
Range
Comments
6..7
Stack VENA Version
E.g. 1234
VENA Version of CCL stack
8.10 Configuration Commands
This group of commands configures the module.
8.10.1 Read ‘S’ Register
Configure the module using 32 bit integer values, which can be stored in non-volatile memory.
Valid register numbers are in the range 0 to 255.
See the S Registers section for a full list of all registers.
The following command reads the current value of the S register REGNO.
Command Packet
Offset
Field
Value
Comments
0
LENGTH
5
Fixed
1
CHANNEL
0
Fixed
2
COMMAND
[CMD_READ_SREG]
3
FLOW_IN
??
Runtime value
4
REGNO
0 to 255
Response Packet
Offset
Field
Value
Comments
0
LENGTH
10
Fixed
1
CHANNEL
0
Fixed
2
COMMAND
[CMD_READ_SREG]
3
FLOW_OUT
??
Runtime value
4
STATUS
As appropriate
5
REGNO
0 to 255
Echoed from Command