User's Manual
Class 1 Bluetooth v2.0 Module
User’s Guide
Americas: +1-800-492-2320 Option 2
Europe: +44-1628-858-940
Hong Kong: +852-2923-0610
www.lairdtech.com/bluetooth
26
CONN-GUIDE-BT730_v0.9
Reg.
#
Defaul
t
Range
Comment
S507
0
0..2
When set to 0, a connection can be dropped using ^^^ escape
sequence only and the state of DSR line is ignored.
When set to 1, a connection can be dropped using EITHER the ^^^
escape sequence OR the DSR handshaking line. When set to 2, a
connection can only dropped using a deassertion of DSR. Mode 2
provides for the highest data transfer rate.
If the status of the DSR line is to be conveyed to the remote device
as a low bandwidth signal then this register MUST be set to 0,
otherwise a deassertion of DSR will be seen as a request to drop the
Bluetooth connection.
This register affects S Register 536 – see details of 536.
For the Go blue Activator variant this can only be set to 0.
S508
640
10..2550
Page Scan Interval in milliseconds. Minimum is 11.25 ms so 10/11
ms gives 11.25ms.
S509
320
10..2550
Page Scan Window in milliseconds. Minimum is 11.25 ms so 10/11
ms gives 11.25 ms.
S510
640
10..2550
Inquiry Scan Interval in milliseconds. Minimum is 11.25 ms so 10/11
ms gives 11.25ms.
S511
320
10..2550
Inquiry Scan Window in milliseconds. Minimum is 11.25 ms so 10/11
ms gives 11.25 ms.