User's Manual
01/2001, CATTRON
- THEIMEG
TM
Section 4, Page 7
Bottom End Cap subassembly (Figure 4-2).
CAUTION:
All circuit boards are sensitive to electrostatic discharge. Use an anti-static mat
and personal grounding strap (wrist) for all maintenance procedures involving
disassembly and assembly of PS controllers. Failure to comply with this caution
may result in equipment damage and will void our warranty.
Remove the subassembly as follows:
a. Lay controller (1) face down on Anti-Static Mat and remove Battery Pack. Refer to
Removal of Battery Pack, above.
b. Remove five screws (2) using Phillips screwdriver.
c. Carefully withdraw endcap sub-assembly (3) to expose charging socket wiring harness
(4). Using long nosed pliers, carefully disconnect 2-pin connector (5) from its socket
located on the underside of the encoder board.
Figure 4-2. Bottom Endcap Sub-assembly, removal and replacement
Replace the subassembly as follows:
a. Observing correct orientation as illustrated in the cutout above, connect 2-pin connector
(5) to its socket located on the underside of the encoder board.
b. Carefully align endcap subassembly (3) to controller housing (1), taking care not to pinch
charging socket wiring harness (4).
c. Secure endcap sub-assembly (3) using five screws (2).
d. Replace the Battery Pack. Refer to Replacement of Battery Pack, above.
5
4
2
1
3