Instruction Manual
5
that fasten the UV-C head to the filter lid (G). UV-C Head is equipped with anti-loss
screws. You do not need to completely remove the screws. Just unscrew them until
the UV-C Head is disengaged.
5. At this stage it is possible to clean the quartz sleeve (C), if required. To clean
the quartz sleeve, use a damp soft cloth to wipe away limescale and
debris. In case of stubborn dirt, some vinegar may be used. Do not use
detergents or other chemical cleaners.
If it is not necessary to change the
UV-C lamp, go straight to point #10.
6. To access the UV-C lamp (B), remove the Quartz Sleeve (C) by first unscrewing,
about 3 turns, the security screw (K) of the Retaining Flange (E) that fasten it to
the UV-C head. Afterwards turn the Retaining Flange approximately 30 degrees
counterclockwise until the screw is aligned with the arrow present in the UV-C
head and pull to disengage it from its place. Important: the Retaining Flange is
equipped with one anti-loss safety screw. There is no need to remove the screw
completely. Just unscrew the screw until the Retaining Flange is free to be turned
and disengaged from its position.
7. Pull off the Quartz Sleeve including the O-Rings by exerting a slight rotary
movement.
8. Once the Quartz Sleeve is removed, pull out the UV-C lamp (B) away from the lamp
holder (if it is not the first start-up) and replace it with a new one. WARNING - DO
NOT ATTEMPT TO VIEW THE LAMP WHEN LIT! Direct exposure to ultraviolet light
can damage eyes and skin. Do not test the UV-C lamp unless the filter is fully
assembled and closed. IMPORTANT – Use original Laguna spare parts only. Refer
to the Spare Parts List for correct part number identification.
9. Place the Quartz Sleeve (C) and the two O-rings (D) back in their original position.
It is recommended to lubricate the O-Rings with an appropriate lubricant.
IMPORTANT – The Lamp Damper (Y) inside the quartz sleeve must be between the
lamp and the bottom of the quartz sleeve. Do not remove it. IMPORTANT – The
two O-rings (D) of the quartz sleeve (C) must be replaced every time the
unit is opened.
10. Place the retaining flange (E) in its original
position. Simply align the screw with the
arrow and press the flange towards the
UV-C head, then turn the Retaining
Flange approx 30 degrees clockwise in
the direction of the security screw (K). At
this time fasten the Retaining Flange by
screwing the security screw (K) (Fig. 7 -
Fig. 8 - Fig. 9).
11. Check to ensure that the Quartz Sleeve
(C) is not damaged. Check that all the
components are present and have been
reassembled properly. If in doubt, consult
your Laguna dealer.
12. Put the UV-C head (A) back on the filter
lid (G), ensuring that the inner O-ring (F)
is correctly located before securing the
UV-C head with the screws (J).
13. Secure the UV-C head (A) to the filter
lid by refitting the 4 anti-loss screws on
the UV-C Head (J). WARNING – Risk of
Electric Shock: Before powering the
lamp, make sure that ALL O-Rings
are back in their original position,
ALL screws are tightened and there
has not been any damage to the unit.
Before connecting the unit to the
power supply, perform the Filter Wet
Test (see below).
14. The filter is now ready for start-up. Read
and follow all instructions in Filter
Start-up, Operation, and Backwash-
Cleaning.
WINTER STORAGE
The unit must be protected from frost. In cold
winter weather, the unit may be switched off.
It should then be drained of water, removed
from its installation and stored in a dry,
weather-proof area. It is recommended to keep the unit lid open during storage.
FILTER WET TEST
Once the unit is fully assembled, it must be wet tested before connecting to the power
supply. This test must be repeated whenever the lamp and the quartz sleeve are
changed or disassembled.
1) Install the filter and connect it to the pump following all installation instructions.
Do NOT switch on the filter. Switch on the pump only and let it run for 24 hours.
2) After 24 hours, switch off the pump and remove the UV-C head (A) from filter by
unscrewing the 4 screws (J). Do not disassemble more parts.
Fig. 7
E
K
Fig. 9
F
Fig. 8
3) Inspect inside the quartz sleeve (C) for leaks. If you see water inside the quartz
sleeve and around the lamp, do NOT connect the unit to power supply but take it
to an authorized Laguna dealer or contact Laguna Customer Service.
If on the contrary no water is visible inside the quartz sleeve (C), carefully reassemble
the unit and use it normally according to this Installation and Maintenance Guide.
UVC Spare Parts - 230-240V 50Hz
PT1715
PF 3000L
PT1716
PF 6000L
PT1717
PF 10000L
PT1718
PF 14000L
UV-C lamp + 2 pcs O-Rings
B PT1601 PT1601 PT1602 PT1603
Quartz Sleeve + 2 pcs O-Rings
C
D
PT1605 PT1605 PT1606 PT1607
UVC Spare Parts - 120V 60Hz
PT1725 PF
1000 US GAL
PT1726 PF
2000 US GAL
PT1727 PF
3000 US GAL
PT1728 PF
4000 US GAL
UV-C lamp + 2 pcs O-Rings
B PT1701 PT1701 PT1603 PT1703
Quartz Sleeve + 2 pcs O-Rings
C
D
PT1704 PT1704 PT1607 PT1706
Universal Spare Parts (See Product Illustrations)
Pressure Flo
1000/3000
Pressure Flo
2000/6000
Pressure Flo
3000/10000
Pressure Flo
4000/14000
Quartz Sleeve O-Rings (2 pcs)
D PT1707 PT1707 PT1708 PT1708
Quartz Sleeve flange
E PT1711 PT1711 PT1712 PT1712
UV-C Head O-Ring
F
PT1530 PT1530 PT1530 PT1530
Universal Click-fit
H
PT640 PT640 PT640 PT640
Sealing Cap Click-fit
I PT1543 PT1543 PT1543 PT1543
Foam cleaning blades (2 pcs)
L PT1513 PT1513 PT1514 PT1514
Foam Filters kit
M PT1735 PT1736 PT1737 PT1738
Lid sealing O-Ring
P PT1535 PT1535 PT1536 PT1536
BioLava/BioRock
- - PT1739 PT1739 PT1739
Rubber O-Rings
aa PT743 PT743 PT743 PT743
* See Product Illustrations
WARRANTY
To register your warranty or for more information, visit www.hagen.com.
This product is warranted for defects in material or workmanship for a period of three
(3) years from date of purchase. This warranty is valid only under normal operating
conditions for which the product is intended. This warranty does not apply to any
unit that has been subjected to misuse, negligence, tampering, accidental damage
or damage due to faulty packaging or mishandling in transit. This warranty does not
cover normal wear of parts and does not apply to any unit that has been used for
commercial purposes. The UV-C bulb is not covered by the warranty. No liability is
assumed with respect to loss or damage to livestock or personal property irrespective
of the cause thereof. This warranty does not affect your statutory rights. This warranty
does not cover damage or defects caused by or resulting from damages from shipping
or repairs, service or alterations to the product or any of its parts, which have been
performed by a repair person not authorized by Rolf C. Hagen Inc.
RECYCLING
This item bears the selective sorting symbol for waste electronic and
electrical equipment (WEEE). This means that the product must be
handled pursuant to European Directive 2002/96/EC in order to be
recycled or dismantled to minimize its impact on the environment. For
further information please contact your local or regional Authorities.
Electronic products not included in the selective sorting process are
potentially dangerous for the environment and human health due to the presence of
hazardous substances.