User Manual

Laerdal 2 ALS Simulator
Items Included:
ALS Simulator
(1) Adult, Full-body Simulator
(1) Articulating IV Training Arm
(1) Blood Pressure Training Arm
(1) Manikin Lubricant
(1) Interchangeable Pupil Set
(6) Neck Skin Collars
(1) Cricothyroid Membrane Tape Roll
(1) Set of Replacement Pneumothorax Bladders
(2) Mid-Clavicular Bladders
(2) Mid Axillary Bladders
(6) Chest Drain Modules
(1) Blood Pressure Cu
(1) Air Pump
(1) Set of Debrillation Posts
(1) Carry Case
(1) Jacket
(1) Pants
(1) Directions for Use
(1) Laerdal Global Warranty Booklet
Skills Taught:
Airway Management Skills
Assessment of Respirations
Obstructed airway
• Tongue Edema
• Right Lung Blockage
Left Lung Blockage
Both Lung Blockage
Endotracheal intubation
Nasotracheal intubation
Digital intubation
Oropharyngeal airway insertion
Nasopharyngeal airway insertion
Bag Valve Mask
Retrograde intubation
Lightwand intubation
Laryngeal Mask Airway insertion
Laryngeal Tube Insertion
Combitube insertion
Trans-Tracheal Jet Ventilation
Surgical cricothyrotomy
Needle cricothyrotomy
Suctioning techniques
Stomach auscultation to verify proper airway positioning
Head Tilt/Chin Lift
Modied Jaw thrust
Ventilations
Drug Administration
IV insertion, infusion and bolus into peripheral veins of forearm, antecubital
fossa and dorsum of the hand
Subcutaneous and intramuscular injections
Tension Pneumothorax Decompression
Bilateral mid-clavicular sites
Mid-axillary site (Right)
Chest Tube Insertion
Mid-axillary site (Left)
Cardiac Related Skills
3 – 4 lead ECG with over 1100 rhythm variations available for interpretation.
Pacing with variable threshold, with or without capture
Debrillation capabilities (25 -360 joules)
Programmable scenario base algorithms for instructor control
Closed chest compressions
Circulatory Skills
Bilateral carotid pulse
Measurement of Noninvasive Blood Pressure
- Brachial and radial pulses
- Auscultation or palpation of noninvasive blood pressure measurement
- Values to be set for systolic, diastolic pressures, heart rate, auscultatory gap
and volume
Sounds and Speech
Refer to SimPad DFU
Logging and Scenario Functions
Refer to SimPad DFU
Unpack:
The ALS Simulator is packaged without the legs attached. Remove the upper
body and legs from the packaging and attach the legs to the torso.
To attach Right Leg (with enclosed air tank):
1. Remove bladder reservoir from pelvis.
2. Remove blank genitalia module from pelvis.
3. Carefully slide the tubing and wiring exiting the xed bolt from the upper
thigh of the right leg through the connector hole and into internal cavity of
pelvic area. (Photo 1)
4. Continue to advance the bolt and wiring though the connector hole until the
thigh is ush with the pelvis of the manikin.
5. From inside pelvic area, slip the longer air connection tube through the
provided thumb nut, then slip the shorter electronic wire through the
thumbnut.
6. Connect the wire and cable inside the pelvis.
7. Tighten the thumb nut until desired articulation is achieved.
8. Replace bladder reservoir in torso.
9. Replace blank genitalia module in pelvic region of torso.
Photo 1