5.5. WATER OUTLET CONNECTION
The machine is equipped with drainage pipe.
The internal diameter of the pipe is ½ inch therefore it can be attached to any standard ½” rubber holder
General rules for installing outlet
A siphon drain is recommended. When installing it is necessary to follow the following advice:
As the outlet water is at 95°C, the end of the outlet pipe must be fixed to the rubber holder, using the clips
provided.
The outlet pipe must not have any sharp bends and consequent narrowing.
The end of the outlet pipe must be at a height comprised between 400 mm and 800 mm, compared to the
surface the appliance stands on.
The end of the pope must not be immerged in water.
The internal diameter of the outlet pipe must be at least 40 mm.
If possible, install a 50 mm diameter outlet pipe.
The outlet pipe provided with the appliance must not be extended. Any extensions may cause flow-back
problems into the vat.
fig. 6 - Outlet pipe connection. The height of the outlet hole "A", compared to the surface on which the appliance stands, must be:
Min 400 - Max 800
mm.
IMPORTANT
The outlet must comply with international legislation. Our company will accept no
liability for pollution caused by improper use of the machine.
Fig. 7 – adaptor with rubber holder for ½” pipe.