IN STRUC TION MANUA L Laboratory Equipment Pty Ltd email: sales@labec.com.au Ph: 02 9560 2811 • Fax: 02 9560 6131 www.labec.com.
b B-IM0070FSC SPR 80 F E B G H I L M ( 1 ) WATER OUTLET BIN WASSERABLAUF ZELLE 1 ( 2 ) WATER INLET - WATER COOLED WASSERZUFUHR - WASSERGEKÜHLTE 2 ( 3 ) WATER OUTLET - WATER COOLED WASSERABLAUF - WASSERGEKÜHLTE 3 ( 4 ) WATER INLET WASSERZUFUHR 4 ( 5 ) CORD SET KABEL 5 SPR 120 - SPR 165 B-IM0120FSCW B-IMSPR 80 0070FSC 1 I 1 B-IMSPR 120 SPR 165 0120FSCW A 626 590 590 B 529 920 920 C 797 785 785 D 135 135 135 E 80 285 285 F 70 185 185 G 58 130 130 H 57 55 55
Page 1 GENERAL INFORMATION AND INSTALLATION A. INTRODUCTION This manual provides the specifications and the step-by-step procedures for the installation, startup and operation, maintenance and cleaning for the SIMAG SPR 80, SPR 120 and SPR 165 Icemakers. The Electronic Flakers are quality designed, engineered and manufactured. Their ice making systems are thoroughly tested providing the utmost in flexibility to fit the needs of a particular user. NOTE.
Page 2 Make sure that the ice machine is connected to its own circuit and individually fused (see data plate for fuse size). The maximum allowable voltage variation should not exceed -10% and +10% of the data plate rating. Low voltage can cause faulty functioning and may be responsible for serious damage to the overload switch and motor windings.
Page 3 11. Has the Manufacturer’s registration card been filled in properly? Check for correct model and serial number against the serial plate and mail the registration card to the factory. G. 12. Has the owner been given the name and the LABEC Service phone number of the authorized SIMAG Agency serving him? INSTALLATION PRACTICE 1. Hand shut-off valve 2. Water filter 3. Water supply line (flexible hose) 4. 3/4" GAS male fitting 5. Power line 6. Main switch 7. Drain fitting 8. Vented drain 9.