Add: 4thFloor,Building30,No.5Area,CuigangIndustrialZone,Huaide,Fuyong,BaoanDistrict,Shenzhen,China518103
maximum opening state,
When FOD (foreign object alarm) is triggered in the working state, and the clamp
remains closed
4.3.4 Outage
The clamp in the closed state: touch the key, then the clamp is opened, and touch the
key again to close the clamp (Touch failure when Super Capacitor voltage is lower than
main control working voltage)
The clamp in the open state: touch the key, the clamp is closed, and touch the key
again to open the clamp (Touch failure when Super Capacitor voltage is lower than
main control working voltage)
4.4 Circuit protection function
4.4.1 Input under-voltage protection: 5V 4.5V, 9V 8V, when the voltagelower than this
value, the product will not work normally (excluding connecting wire)
4.4.2 Input over-voltage protection: 5V 6V, 9V 10.5V, when the voltage exceeds this
value, the product will not work normally (excluding connecting wire)
4.4.3 FOD foreign object detection: use 25mm diameter metal, stop working after detecting
foreign object
5 Weather conditions standard
5.1 Weather condition
Operating temperature -10 °C ~ +45 °C
Operating humidity:10 % R.H. ~85 % R.H.(No steam condensation)
Storage temperature:-20 ~ +65 °C
Storage humidity:Less than 75 % R.H.
6、 Operating environment and maintenance
6.1 Do not use this product near a strong magnetic field.
6.2 Please do not use unapproved or incompatible power supply or charger,