Current Draw & Thermal Dissipation

PLM 20K44
Item no. CDTD-PLM20K44 - 07.09.2015
WWW.LABGRUPPEN.COM
PLM 20K44
Level Load
Rated power
per channel
Line Current
Power
Factor
Measured Power (W) Thermal Dissipation
(A) (%) In Out Dissipated BTU/hr kCal/hr
Mains Voltage 230 VAC, 16 A
Standby 0.3 23 18 0 18 61 15
Power on, Idling 1.2 92 222 0 222 757 191
Pink Pseudo
Noise
16 Ω / Ch. 115 0 5.1 98 113 4 588 546 1863 470
8 Ω / Ch. 2300 9.2 99 2053 1174 879 2999 756
4 Ω / Ch. 4400 15.9 99 3529 2109 1420 4845 1222
2.67 Ω / Ch. 5000 16.0 99 3564 1935 1630 5561 1402
2 Ω / Ch. 4400 16.0 99 3577 1856 1722 5875 1481
LoadPilot
Sine 20 kHz
8 Ω / Ch. 1.1 90 228 0 228 777 196
Current Draw and Thermal Dissipation
PLM+ SERIES: Powered Loudspeaker Management System