13.2. Software installation and firmware update
13.2.1. Lake Controller software suite
1. The Lake controller software suite includes the Lake controller and accompanying utilities: Lake LoadLibrary
and Dante discovery services. Download the Lake Controller installation from www.labgruppen.com.
2. Execute the installer and follow the on-screen instructions. This is a typical software installation where the
default settings are acceptable for the vast majority of users.
13.2.2. CAFÉ software
1. The CAFÉ software is available as a separate installer on www.labgruppen.com.
2. Execute the installer and follow the on-screen instructions. This is a typical software installation where the
default settings are acceptable for the vast majority of users.
13.2.3. Firmware update
The latest rmware for the product is included in the Lake controller installation. It is likely that rmware installed on
the new product is older and requires updating.
1. Make sure all frames are powered on and connected through a wired network.
2. Launch the Lake rmware update utility LakeUpdate.exe.
3. Select the appropriate product range.
4. If more than one network adapter is enabled, a prompt will appear requiring selection of the adapter connected
to the frames.
5. If prompted, allow the application access through the Firewall.
6. Latest rmware is preselected.
7. Discovered frames are listed. Tap Select Old and Update to initiate rmware update of all outdated frames.
Frames already up to date will not be selected.
8. Read warning message and tap OK.
9. Wait for all updates to be completed. A wait indication will display on the unit(s) during updating.
(Four corner LEDs will blink yellow in circular pattern.)
10. Follow the on screen instructions. Ampliers with rmware associated with Lake Controller 6.5.0 or later will
automatically power cycle the mains power, whereas ampliers with older rmware will display a message
that a manual power cycle is required (Note: A manual power cycle requires the mains plug to be completely
removed, the standby button does not complete the rmware update.)
11. If internal updates are needed, these will be performed by the frame after the power cycle.
A wait indication is displayed.
12. Tap Exit to close the update utility.