Operation Manual
7. Front Panel Interface
PLM+ SERIES Operation Manual rev 3.0.4
37
7.8.4.1. Mute Functions
The PLM+ provides mute functions at several different points in its audio chain. Please refer to section 6.1 for
further information. The four types of mute are:
1. PLM+ Input Router Mute
2. Module Input Mute
3. Module Output Mute
4. Power Output Mute
With the exception of Module output mutes, all types may be controlled from the PLM+ front panel in Meter Mode
by activating MUTE ENABLE and selecting the associated input or output Meter View using the METER button.
Module Ouput Mute is available in Menu mode Module > Mute.
NOTE: Module input and output mutes can be controlled in Menu Mode via the MENU button. All
mutes can also be controlled from the Lake Controller.
7.8.4.2. PLM+ Input Router Mute
The PLM+ Input Router mute provides the ability to simultaneously mute/unmute all modules or outputs that are
sourced from the PLM+ input. To mute or unmute the PLM+ inputs:
1. Press METER until the Input Meter View is displayed
2. Press MUTE ENABLE
3. Use the associated dynamic function buttons to mute / unmute the PLM+ input router to the left.
NOTE: The PLM+ Input Router Mute is within the Lake Processing system, post input type selection,
and pre input mixing and routing.
Please refer to the Lake Controller User Manual for details of mute selection via the software.
7.8.4.3. Module Input Mute
The Module input mute provides the ability to mute/unmute the audio signal at the module level. Therefore, the
PLM+ Input Router (described in section 7.8.4.2) remains unmuted and can be used by another module. To mute
or unmute a Module input:
1. Press METER until Home View is displayed
2. Press MUTE ENABLE
3. Use the associated dynamic function buttons to mute / unmute the Module inputs
Once the Module input is muted, the LED turns red and MOD. IN MUTE is displayed on the LCD. When unmuted,
the LED turns green (unless any other output warning conditions are active).
7. Front Panel Interface
38
PLM+ SERIES Operation Manual rev 3.0.4
NOTE: Fault condition LED indications take priority over mute status indications. If a fault condition
occurs, the LED will indicate the fault by ashing and will note the mute status. When a Frame fault is
active the audio on all channels is muted.
Module Input Mutes may also be controlled in Menu Mode.
Please refer to the Lake Controller User Manual for details of mute selection via the software.
7.8.4.4. Module Output Mute
Module Output Mute is part of the Lake Processing system, at the crossover outputs. It is post Module output EQ
and level adjustment, pre PLM+’s protection circuitry.
Muting of the Module outputs is available via MUTE ENABLE in Module Meters view, as the PLM+ power output
mutes are assigned in this mode (see section 7.8.4.5). However, Module output mute status and control are also
available in Menu Mode and may also be viewed and controlled from the Lake Controller software.
Please refer to section 7.11.2.7 for details of selecting Module Output Mute in Menu Mode.
Refer to the Lake Controller User Manual for details of mute selection via the software.
7.8.4.5. Power Channel Mute
The four dynamic function buttons to the right of the LCD control the Power Output Mutes of output channels 1-4.
These mutes are located within the PLM+’s power output stage.
When a PLM+ power output is muted, the LED turns red and the text AMP CH. MUTE is displayed on the LCD.
When unmuted, the LED turns green (unless any other output warning conditions are active).
NOTE: Fault condition LED indications take priority over mute status indications. If a fault condition
occurs, the LED will indicate the fault and not the mute status.
7. Front Panel Interface
39
PLM+ SERIES Operation Manual rev 3.0.4