Current Draw & Thermal Dissipation

LUCIA® 60/2
The following tables contain information on measured current consumption as well as calculated heat dissipation during what we see as the
most extreme sustained normal operation (1/8 rated power).
WWW.LABGRUPPEN.COM
LUCIA 60/2
Level Load
Output
power
Mains
voltage
Line
current
Watt *1) Thermal Dissipation
VAC IAC In Out Dissipated BTU/hr kCal/hr
Standby w. remote Power O .
230 0.03 1 0 1 3 1
120 0.03 1 0 1 3 1
100 0.03 1 0 1 3 1
Power on, Idling
230 0.1 12 0 12 41 10
120 0.2 13 0 13 44 11
100 0.2 13 0 13 45 11
Pink Pseudo
Noise (1/8)
16 Ω / Ch. 15 x 2
230 0.2 19 4 15 51 13
120 0.3 19 4 15 51 13
100 0.3 19 4 15 51 13
8 Ω / Ch. 30 x 2
230 0.2 24 8 16 55 14
120 0.3 23 8 16 54 14
100 0.4 24 8 16 55 14
4 Ω / Ch. 30 x 2
230 0.2 24 8 17 57 14
120 0.3 24 8 16 56 14
100 0.4 24 8 17 57 14
2 Ω / Ch. 30 x 2
230 0.2 25 8 17 59 15
120 0.3 25 8 17 58 15
100 0.4 25 8 17 59 15
*1) The ampli er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and speci ed here is what is
known as the “Active Power” in the ampli er providing useful, real-world values of power consumption and heat dissipation.
Item no. CDTD-LUCIA 120170 10:4 - 11.01.2017
Current Draw and Thermal Dissipation
LUCIA: Localized Utility Compact Intelligent Amplifi cation