Current Draw & Thermal Dissipation
Current Draw and Thermal Dissipation
LUCIA: Localized Utility Compact Intelligent Amplification
LUCIA® 120/1-70
Item no. CDTD-LUCIA120170 - 12.06.2015
WWW.LABGRUPPEN.COM
The following tables contain information on measured current consumption as well as calculated heat dissipation during what we see as
the most extreme sustained normal operation (1/8 rated power).
LUCIA 120/1-70
Level Load Output power
Mains
voltage
Line
current
Watt *1) Thermal Dissipation
VAC IAC In Out Dissipated BTU/hr kCal/hr
Standby w. remote Power Off.
230 0.032 0.88 0 1 3 1
120 0.027 0.77 0 1 3 1
100 0.028 0.76 0 1 3 1
Power on, Idling
230 0.21 11.9 0 12 41 10
120 0.19 13.0 0 13 44 11
100 0.22 13 .1 0 13 45 11
Pink Pseudo
Noise (1/8)
70 V 120 x 1
230 0.30 35.6 15 21 70 18
120 0.47 33.6 15 19 63 16
100 0.54 34.4 15 19 66 17
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specified here
is what is known as the “Active Power” in the amplifier providing useful, real-world values of power consumption and heat dissipation.