Operation Manual
FP+ Series Operation Manual 30
TECHNICAL SPECIFICATIONS 7
Following are the FP+ Series technical speci cations. These gures are accurate at the time of printing but
please note that all gures are subject to change without notice. For the most accurate and current information
available, please visit www.labgruppen.com.
Model
Number of channels
Peak total output all channels driven
Peak output voltage per channel
Max. output current per channel
Max. Output Power
16 ohms per ch. (all ch.’s driven)
8 ohms per ch. (all ch.’s driven)
4 ohms per ch. (all ch.’s driven)
2 ohms per ch. (all ch.’s driven)
16 ohms Bridged per ch.
8 ohms Bridged per ch.
4 ohms Bridged per ch.
2 ohms Bridged per ch.
Performance with Gain:
THD 20 Hz - 20 kHz for 1 W <0 .1%
THD at 1 kHz and 1 dB below clipping <0.05%
Signal To Noise Ratio >112 dB
Channel separation (Crosstalk) at 1 kHz >70 dB
Frequency response (1 W into 8 ohms) +0/-3 dB
Input Impedance 20 kOhm
Common Mode Rejection (CMR) >54 dB, 20 Hz to 20 kHz
Output impedance @ 100 Hz
Voltage Peak Limiter (VPL), max. peak output
VPL, selectable per ch. (V)
VPL, selectable when bridged (V)
1)
Voltage Peak Limiter mode (per ch.) Hard / Soft
Gain and Level
Ampli er gain selectable (all channels)
1)
– rear-panel switches
23, 26, 29, 32, 35, 38, 41, 44 dB
Default gain
Level adjustment (per ch.) Front-panel potentiometer, 31 position detented from -inf to 0 dB
Connectors and switches
Input connectors (per ch.) 3-pin XLR, electronically balanced
Output connectors (per ch.) Neutrik speakON or Binding Posts (must be specified upon order). BP only on FP 14000, FP 13000, FP 9000.
Output bridge mode per two ch.’s A+B - Ch. A is signal input source. A+B, C+D - Ch.’s A and C are input source
NomadLink network 2 x RJ45 etherCON connectors, IN and OUT
Intelligent fans (on/off) Yes, depending on presence of output signal
Power on/off and Remote enable on/off Individual switches on front-panel
Cooling Two fans, front-to-rear air ow, temperature controlled speed
Front-panel indicators
Common NomadLink
network; Power Average Limiter (PAL)
2)
; Power on
Per channel Signal present / High-impedance; -20 dB, -15 dB, -10 dB and -4 dB output
signal; Voltage Peak Limiter (VPL); Current Peak Limiter (CPL):
Very High Frequency (VHF); High temperature; Fault; Mute
Power
Operating voltage, 230 V / 115 V nominal
4)
130-265 V / 65 -135 V
Minimum power-up voltage, 230 V / 115 V 171 V / 85 V
Power Average Limiter (PAL)
2)
Yes
Soft start / Inrush Current Draw Yes / max. 5 A
Mains connector
230 V CE: 16 A, CEE7; 115 V ETL: 30 A Twist lock | FP 4000:
230 V CE: 16 A, CEE7; 115 V ETL: 20 A / NEMA 5-20P
Dimensions W: 483 mm (19”), H: 88 mm (2 U), Overall D: 396 mm (15.6”), Mounting D: 358 mm (14.1”)
Weight 12 kg (26.4 lbs.)
Finish Black painted steel chassis with black painted steel / aluminum front
Approvals CE, ANSI/UL 60065 (ETL), CSA C22.2 NO. 60065, FCC
Note 1): Automatic -6 dB gain compensation when bridging channels.
Note 2): PAL can reduce the maximum output power to keep the power supply operating safely, and/or to prevent excessive current draw tripping the mains breaker.
Refer to the FP+ Operation Manual section 7.5.8 Power Average Limiter (PAL) for more information.
Note 3): The amplifier will be fully operational at bridge-mode 2 ohm loads, but due to physical constraints in the construction, the max. output power will not be
significantly higher than running individual channels and therefore not stated here.
Note 4): Separate 230 V or 115 V versions available. Not selectable on the amplifier.
All specifications are subject to change without notice.
FP 14000 FP 9000 FP 7000 FP 4000 FP 10000Q FP 6000Q
2 2 2 2 4 4
14000 W 9000 W 7000 W 4000 W 10000 W 6000 W
195 V 170 V 155 V 121 V 150 V 101 V
90 A peak
70 A peak 59 A peak 50 A peak 50 A peak 38 A peak
1200 W 800 W 730 W 400 W 660 W 320 W
2350 W 1600 W 1450 W 800 W 1300 W 625 W
4400 W 3000 W 2800 W 1600 W 2100 W 1250 W
7000 W 4500 W 3500 W 2000 W 2500 W 1500 W
4700 W 3200 W 2900 W 1600 W 2600 W 1250 W
8800 W 6000 W 5600 W 3200 W 4200 W 2500 W
14000 W 9000 W 7000 W 4000 W 5000 W 3000 W
3) 3) 3) 3) 3) 3)
35 dB and VPL: 195 V
35 dB and VPL: 170 V
35 dB and VPL: 155 V
35 dB and VPL: 121 V
35 dB and VPL: 150 V 35 dB and VPL: 101 V
2 Hz - 34.2 kHz 2 Hz - 34.2 kHz 6.8 Hz - 34 kHz 2 Hz - 34.2 kHz 6.8 Hz - 34 kHz 6.8 Hz - 34 kHz
19 mOhm 19 mOhm 19 mOhm 32 mOhm 32 mOhm 32 mOhm
195, 170, 140, 116,
100, 80, 66, 54 V
170, 140, 116, 100,
80, 66, 54 V
155, 121, 101, 83,
70, 56, 47, 38 V
121, 101, 83, 70, 56,
47, 38 V
150, 121, 101, 83,
70, 56, 47, 38 V
101, 83, 70, 56, 47,
38 V
390, 340, 280, 232,
200, 160, 132, 108 V
340, 280, 232, 200,
160, 132, 108 V
310, 242, 202, 166,
140, 112, 94, 76 V
242, 202, 166, 140,
112, 94, 76 V
300, 242, 202, 166,
140, 112, 94, 76 V
202, 166, 140, 112,
94, 76 V
38 dB 38 dB 35 dB 35 dB 35 dB 35 dB