Operation Manual
29 FP+ Series Operation Manual
FP 6000Q
Level Load Rated power
Line Current *2) Watt *1) Thermal Dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
Standby with remote power off via Nomadlink
®
0 0 0 0 0
Power on, Idling 134 0 134 456 115
Amp (I) Watt
Pink noise
(1/8th rated
power)
16 Ω / Ch. 320 x 4
6.7 3.5 423 160 263 898 226
32 Ω / Bridged 640 x 2
8 Ω / Ch. 625 x 4
10.5 5.4 700 313 388 1323 333
16 Ω / Bridged 1250 x 2
4 Ω / Ch. 1250 x 4
17. 3 9.0 1215 625 590 2015 508
8 Ω / Bridged 2500 x 2
2 Ω / Ch. 1500 x 4
21.9 11.4 1575 750 825 2817 710
4 Ω / Bridged 3000 x 2
Pink noise
(max power)
*3)
16 Ω / Ch. 320 x 4
11. 4 5.9 771 427 344 1175 296
32 Ω / Bridged 640 x 2
8 Ω / Ch. 625 x 4
19.2 10.0 1402 833 569 1942 489
16 Ω / Bridged 1250 x 2
4 Ω / Ch. 1250 x 4
30.0 16.0 2249 / 2305 1310 / 1350 939 / 955 3203 / 3261 807 / 822
8 Ω / Bridged 2500 x 2
2 Ω / Ch. 1500 x 4
30.0 16.0 2244 / 2300 1329 / 1384 915 / 916 3122 / 3125 786 / 787
4 Ω / Bridged 3000 x 2
Mains connector, 230 V CE version 16 A, CEE7
Mains connector, 115 V ETL version 30 A, Twist lock
*1) The ampli er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and speci ed here
is what is known as the “Active Power” of the ampli er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw gures measured at 230 V. 115 V gures are 230 V gures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily in excess of max. ratings.
6 APPENDIX
Table 6.4g: FP 6000Q Current Draw and Thermal Dissipation specications